dc.contributor.authorXie, Yanmei
dc.description.abstractAir cavity behind claddings within building envelope provides an approach to mitigating building moisture-related issues as well as improving the building’s thermal performance. However, studies in literature commonly assume the cavity air as still and thus neglect the influence of mixed convection on the performance of building envelope. In addition, the drying performance of the air cavities remains unknown, and commonly a rectangular unicellular cavity is improperly assumed to simplify the investigation of the hygrothermal performance of a cladding system. Moreover, the literature lacks a study of the effect of humid air in the air cavity on heat and mass transfer. Therefore, it necessitates advanced problem formulation and solving to comprehensively study the effects of air cavities behind claddings on the performance of building envelope. The specific objectives are to 1) investigate potential of self-drying siding with raised air cavities for building envelopes; 2) study the effects of the cavity depth in mixed convection of air cavity for building envelopes; 3) analyze the effects of humid air in an air cavity on mass and heat transfer with phase change at the wall. To achieve these objectives, firstly, this study redefines the drying potential of air cavity taking into account the air cavity depth related to the shape irregularity and the inlet and outlet uncertainties. Then the formulated problems of mixed convection of air cavities behind sidings are solved with a perturbation method and SIMPLER algorithm. The results show that the drying performance is found to be heavily dependent on the cavity depth. Further, increasing the ratio of the siding depth to the air cavity depth amplifies the cavity air’s velocity, temperature, and mass fraction at cavity walls, as well as the heat and mass transfer across cavities. Consequently, this study demonstrated that humid air with the phase change and the cavity depth have the significant effects on the hygrothermal performance of building envelopes. The outcome of this study provides valuable guidance on the thermal performance evaluation of air cavity and has the potential of improving the design of claddings for the overall hygrothermal performance of building envelope.en_US
dc.publisherNorth Dakota State Universityen_US
dc.rightsNDSU policy 190.6.2en_US
dc.titleHygrothermal Effects of Air Cavities Behind Claddings on Building Envelopesen_US
dc.typeDissertationen_US
dc.date.accessioned2023-12-20T16:14:11Z
dc.date.available2023-12-20T16:14:11Z
dc.date.issued2022
dc.identifier.urihttps://hdl.handle.net/10365/33390
dc.subjectAir cavityen_US
dc.subjectcavity depthen_US
dc.subjectdrying potentialen_US
dc.subjecthygrothermal performanceen_US
dc.subjectthermal performanceen_US
dc.rights.urihttps://www.ndsu.edu/fileadmin/policy/190.pdfen_US
ndsu.degreeDoctor of Philosophy (PhD)en_US
ndsu.collegeEngineeringen_US
ndsu.departmentCivil, Construction, and Environmental Engineeringen_US
ndsu.programCivil Engineeringen_US
ndsu.advisorYang, Huojun